Produktname: Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Marke: Dynisco
Produktcode: MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Stichwörter: Dynisco
Dynisco MDT422F-1/2-1C-15/46-A Melt
MDT422F-1/2-1C-15/46-A Pressure
MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Melt Pressure
MDT422F-1/2-1C-15/46-A Transmitters
Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure
MDT422F-1/2-1C-15/46-A Melt Transmitters
Pressure Transmitters
Transmitters
Dynisco MDT422F-1/2-1C-15/46-A Pressure Transmitters
MDT422F-1/2-1C-15/46-A Pressure Transmitters
Dynisco MDT422F-1/2-1C-15/46-A
Dynisco MDT422F-1/2-1C-15/46-A Pressure
Dynisco MDT422F-1/2-1C-15/46-A Transmitters
Melt Transmitters
MDT422F-1/2-1C-15/46-A Melt Pressure
Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters
Dynisco Melt
Dynisco Transmitters
Interessieren Sie sich für das Produkt Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters vom Hersteller Dynisco mit dem Code MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters? Kontaktieren Sie uns jetzt und holen Sie sich ein Angebot. Imtek Engineering, der schnellste und zuverlässigste Lieferant von Industrieausrüstung der Welt, wird Ihnen das beste Angebot machen!
Angebot per E-Mail erhalten: info@im-tek.com
Holen Sie sich jetzt ein Angebot für Dynisco MDT422F-1/2-1C-15/46-A Melt Pressure Transmitters von unserem Live-Support-Team!
Installation for media temperature up to 400°CFlexible capillary between rigid stem and housingElectrical built-in calibrationVarious high level outputs4-20 mA, 2-wire 0-10 V DC, 3/4-wire and other volt output signal rangesPerformance Characteristics Pressure Range: 0-17 bar to 0-2000 barAccuracy: MDT422F ±0.5% FSO (up to 50 bar ±1% FSO);Repeatability: MDT422F ±0.1% FSO (up to 50 bar ±0.2% FSO); MDT462F ±0.2% FSOResolution: Infinite Maximum Overload (without in"uencing operating data): 2x pressure range for range 1000 and 1400Burst Pressure: 6x pressure range max. 3000 bar Material in Contact with Media: 15-5 PH SST (Mat. No. 1.4545)DyMax® coated Electrical Characteristics Confguration: 4-armWheatstone bridge strain gage Internal Shunt Calibration: 80% of full scale ±1% Output Signal: 2-wire 4-20 mASupply Voltage: 12-36 Vdc Zero Balance: ±1%Rezero Initiation: Locally via zero potentiometer, or remotely via short circuit between pins “D” and “F” Range Calibration 80% FSO: “Short circuit” between connections pins “E” and “F” at the sensor or externally from the control roomLoad Resistance: Maximum 1200 at 36 Vdc Maximum 500 at 24 VdcIsolation Resistance: 1000M* at 50 VdcTemperature Influence Diaphragm: Max.Temperature: 400ºC Zero Shift (due to temperature change): MDT422F X < 0.2 bar/10ºC MDT462F X < 0.4 bar/10ºC Housing: Max.Temperature: 85ºC Zero Shift (due to temperature change): ±0.2% FSO/10ºCSensitivity Shift (due to temperature change): MDT422 X ±0.1% f.s.v./10ºC up to 50 bar ±0.2% f.s.v./10ºC MDT462 X ±0.4% f.s.v./10ºC Approvals &Self Certifications CE: Directive 2004/108/EC ISO