Produktname: Tecsis FSK01 Test Set For Measurement Of Electrode Forces
Marke: Tecsis
Produktcode: FSK01
Stichwörter: Tecsis
FSK01 Set For Of Electrode
Tecsis FSK01 Test Set For Measurement
Test Set Measurement Of
FSK01 Test Set For Forces
Tecsis Test For Of Electrode
Test For Measurement Of
For Measurement Of Forces
Tecsis Set Of Electrode
FSK01 Set For
Tecsis Forces
FSK01 Test For Measurement Forces
FSK01 Test Set For
Set Of Electrode
For Measurement
FSK01 Electrode Forces
Test Measurement Electrode Forces
Tecsis FSK01 For Of Forces
FSK01 Test Set Electrode
FSK01 Measurement Of Electrode Forces
FSK01 Set For Forces
Test Set For Measurement Of Electrode Forces
Interessieren Sie sich für das Produkt Tecsis FSK01 Test Set For Measurement Of Electrode Forces vom Hersteller Tecsis mit dem Code FSK01? Kontaktieren Sie uns jetzt und holen Sie sich ein Angebot. Imtek Engineering, der schnellste und zuverlässigste Lieferant von Industrieausrüstung der Welt, wird Ihnen das beste Angebot machen!
Angebot per E-Mail erhalten: info@im-tek.com
Holen Sie sich jetzt ein Angebot für Tecsis FSK01 Test Set For Measurement Of Electrode Forces von unserem Live-Support-Team!
Applications Measurement of electrode forces for spot welding equipment Special features Measuring ranges 10 kN, 20 kN Relative linearity error 0.2 % Fnom Low overall weight of approx. 6 kg Maximum/Minimum value memory Electrode diameter 14 … 20 mm Description The test set is used for the monitoring of electrode forces for spot welding equipment. The set consists of a force transducer and display unit. To test the forces acting between the electrodes, the force transducer is held between the electrodes. The concave force introduction surfaces centre the force transducer. When the welding electrodes come together, the magnitude of the applied force can be read off the indicator. The force transducer is designed as a shear beam load cell. It is insensitive to lateral forces and moments. The output signal is fed to the indicator via a cable. This also supplies the force transducer with its operating voltage. Alternatively, the supply voltage can also be taken from a PLC. In this type of force transducer, proven thin-film sensor technology is integrated. The laser-welded sensor has all the advantages of conventional glued film strain gauges, without, however, being affected by their major disadvantages (temperature behaviour of the adhesive and creep).CalibrationForce transducer and indicator are calibrated together as a measuring chain. A repeat calibration is recommended every 12 months. This service can be carried out quickly and reliably by WIKA.Scope of deliveryHand-held indicator, force transducer, plastic case, charger, 2 m signal cable, manufacturer's test certificate