im-tek.com

Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco SPX 4222 N-A-00-B-17-CE-DD-A-AF-ZZ-GC8 Pressure Sensors
Dynisco PT482-1/2-5M-6/18-B379 Pressure Sensors
Dynisco PT160-5M Pressure Sensors
Dynisco MDT422F-1/2-3.5C-32/46-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco ATC990-4-0-1-1-1-1-0-0-0 Process Controller
Dynisco MDT420L-1/2-7C-15 Melt Presure Transmitters
Dynisco TPT463E-5CB-6/18 Pressure Sensors
Dynisco MDT467F-1/2-2C-SIL2 Melt Pressure Transmitters
Dynisco VERT-MV3-MM1-NDC-PSI-R17-UNF-6PN-S06-NFL-NTR-NCC Melt Pressure Sensor
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ECHO-MV3-BAR-R22-UNF-6PN-S06-NFL-NTR Melt Pressure Transducers
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR/ E12611121 Pressure Sensor
Dynisco TDT463F-1/2-3,5C-15/46-A Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Dynisco DYMT-S-1/2-RTD-15-15-G Melt Temperature Probe
Dynisco ECHO-MA4-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Sensors
Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Amot 1125X110 Valve Element
KSB BPC 241/08+UMAI 125-5.5/22 Pump
Habasit HAT-8P Belt
Hengstler AC58/1214ES.41DPZ Absolute Encoder
Grundfos SRG.40.30 .593.25.5.1B Submersible Wastewater Pumps
Greisinger GIA0420 Display
Rebs SP-VM Oil-Air Mixing Block
Eaton Vickers (Danfoss) DG4V-3S-66C-M-KUP6-G7-60-EN642-P15 Solenoid Valve
NSD VS-5F-1 VARICAM Cam Switch Output Controller
Scherzinger 4040-450-ZK80-160 Hastelloy (R) Gear Pumps 4040
Steimel PSF8/300RD122137R Pump
Alfa Laval TE67G411151630 TT: ´-20 to 150 °C 6mm tip,15 cm Clamp 1½",M12 Plug,N/A
Stahl FX15/C-F-050-A-EN-SF-A-ST-00-00-00 Visual Signalling Device
Asco Joucomatic 881 22 602 Connector Kit
Honsberg UR1-010GM Flow Switch
KSB MCPK040-025-200 GG NP2 A Pump
Ru-Steel ACC 12 Elastics
Yuken DSHG-04-3C4 Check Valve
Atlas Copco 2901990101 Prev. Maint. Kit C142 Ga75vsd+
Mahle Pi 241008/1C/N-058 70535440 Duplex Filter
Mp Filter MPF 1003 AG2 A10 HB P01 Hydraulic Filter
Bürkert 423849 2507-01-B-00-3-3-024 Cable Plug & Connector
Vogel MKU1-13DC10000 428 Single Line Pump
Winsmith 4FCV Single Reduction Fan Cooled Speed Reducer