97% customer satisfaction based on last 45 days of sales
Order Processing & Delivery Information:
As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Get the best price and fastest delivery for Kirchgaesser FDR57/FQR57 with FTR525 Microwave Barrier from Kirchgaesser. Imtek Engineering offers worldwide industrial equipment supply with expert support.
| FQR57 / FDR57 | FTR525 | |
| Detection range point level: | Max. 100 m | – |
| Detection range flow: | Max. 10 m, depending on bulk solids | – |
| Operating frequency: | 24.05…24.25 GHz ISM | – |
| Electrical connection: | Cable gland M20Thread ANSI ½ NPTBinder connector type M12 series 713/763Harting connector type HAN8D | Plug-in terminals |
| Output signal: | Serial signal for the FTR525 | 1x (optional 2x) relay SPDT + 4-20 mA + alarm open collector1x (optional 2x) solid-state relay + 4-20 mA + alarm open collector |
| Power supply: | Supply via the FTR525 | 24...230 VDC (-15%/+10%) resp. 42...230 VAC (-15%/+10%), 50/60Hz |
| Housing: | PolyesterAluminumStainless steel 316L | Polycarbonate GRP |
| Process connection: | Thread R 1½ in accordance with EN 10226Thread G 1½ in accordance with ISO 228-1Thread 1½ NPT in accordance with ANSI/ASME | – |
| Optional process connection: | FlangeSight glassHigh-temperature adapterHigh-pressure adapterMounting bracketStructured accessories FAR50, FAR51, FAR52, FAR53, FAR54 and FAR55Individual customer solutions | – |
| Main wetted parts: | Contactless installation: noMounting: 316Ti, PTFE or ceramic | – |
| Ambient temperature: | -40...+70 °C | -20...+60 °C |
| Process temperature: | Contactless installation: anyMounting: -40...+70 °C, with high-temperature adapter -40... +450 °C | – |
| Process pressure: | Contactless installation: anyMounting: 0.5...6.8 bar (50...680 kPa) abs., with high-pressure adapter 0.5...21 bar (50...2100 kPa) abs. | – |
| Protection acc. to EN 60529: | IP 66 | IP 20 |
| Vibration resistance - Endurance stress with sliding frequency acc. to EN 60068-2-6: | Excitation mode: sineFrequency range: 10...55 HzAmplitude: 0.75 mm peak constantSpeed of sweep: 1 oct / minExcitation direction: 3 directions (X, Y, Z)Number of cycles: 20 / directionTest duration: approx. 1 h 38 min / directionTest temperature: room temperature | – |
| Marking acc. to 2014/34/EU (ATEX): | ATEX II 1G Ex ia IIC T4 Ga / ATEX II 1D Ex ia IIIC T135°C DaATEX II 1/2G Ex ia IIC T4 Ga/Gb / ATEX II 1/2D Ex ia IIIC T135°C Da/Db(BVS 18 ATEX E 024 X) | ATEX II (1)G [Ex ia Ga] IIC / ATEX II (1)D [Ex ia Da] IIIC (BVS 18 ATEX E 024 X) |
| Marking acc. to IECEx: | IEC Ex ia IIC T4 Ga / IEC Ex ia IIIC T135°C DaIEC Ex ia IIC T4 Ga/Gb / IEC Ex ia IIIC T135°C Da/Db(IECEx BVS 18.0042X) | IEC [Ex ia Ga] IIC / IEC [Ex ia Da] IIIC (IECEx BVS 18.0042X) |
| Radio approval: | EN 300440 - Short range radio devices (SRD) – radio devices for operation in a frequency range of 1 GHz to 40 GHzFCC Rule Parts 15CIC according to RSS-Gen Issue 4 and RSS-310 | – |